External level switch online shopping with drurylandetheatre.com
External level switch online shopping by drurylandetheatre.com? Liquid level controller refers to the control of high and low liquid levels through mechanical or electronic methods. It Can control solenoid valves, water pumps, etc. So as to achieve semi-automation or full automation. There are many methods, depending on the choice of different products. The float type liquid level controller is composed of a magnetic float, a measuring tube, a signal unit, an electronic unit, a junction box and installation parts. Generally, the specific gravity of the magnetic float is less than 0.5, which can float on the liquid surface and move up and down along the measuring tube. A measuring element is installed in the catheter. It can convert the measured liquid level signal into a resistance signal proportional to the change of liquid level under the action of external magnetism. And convert the electronic unit into 4-20ma or other standard signal output.
The advantages of ultrasonic liquid level gauge are very outstanding. It is mainly reflected in the following aspects : Adopt non-contact measurement. It is not easily affected by the viscosity and density of the liquid. Of course, the ultrasonic liquid level gauge also has its own limitations and insurmountable defects. Specifically, it is mainly manifested in: Ultrasonic liquid level gauge should not be used to measure pressure vessels. Because the pressure mainly affects the probe. There is also a certain relationship between the pressure and the temperature. The change in pressure will affect the change in temperature. This will affect the change in the speed of sound. The accuracy of the measurement will be affected.
In the measurement, the ultrasonic pulse is emitted by the sensor (transducer), and the sound wave is reflected by the liquid surface and then received by the same sensor or ultrasonic receiver. Through piezoelectric crystal or magnetostrictive device into electrical signals. The distance between the sensor and the measured liquid surface is calculated by the time between the transmission and reception of sound waves. Read even more details at ultrasonic water level sensor.
For spherical tanks equipped with a calibrator. The calibration sensor is installed at the center of the calibrator on the outer wall of the tank. If the calibrator is not installed, the calibration sensor should be installed at the height of the outer radius of the tank (equatorial zone). The calibration sensors for the vertical tank and the process tank are installed on the outer side of the tank body, at a height of 0.5m to 1m from the tank bottom. Note: After installing the calibration tube (calibrator) in the tank, the correct installation position should be marked with paint on the outside of the tank wall in time.
What is ultrasonic level sensor? Ultrasonic level sensor is a monitoring instrument for measuring liquid height, tank height, and material position. The ultrasonic level sensor can adopt two-wire, three-wire or four-wire technology. The two-wire system is: power supply and signal output are shared. The three-wire system is: the power supply circuit and the signal output circuit are independent. When using DC 24v power supply, a 3-core cable can be used, and the negative terminal of the power supply and the negative terminal of the signal output share a core wire. The four-wire system is: when using AC 220v power supply, or when using DC 24v power supply. When the power supply loop and the signal output loop are required to be completely isolated. A 4-core cable should be used. See more information at this website.